MOTOR Vision

For monitoring motor operating conditions

MOTOR Vision means "smart" motor starters connected to the California Motor Control PUMP Vision controller.  This provides the user easy access to motor operating data such as volts, amperes, ground fault current, power factor and much more.  The purpose of MOTOR Vision is to provide proactive protection of the pump against such conditions as running dry, mechanical jam and power problems.

 

 

PUMP Vision TS350

Screens are provided in the PUMP Vision controller to monitor and setup the MOTOR Vision starter.  The main monitoring screen provides*:

  • Voltage per phase, average and imbalance
  • Amperes per phase, average and imbalance
  • Frequency
  • Power factor
  • Ground fault

 

 

*depending on which MOTOR Vision solution is connected.

 

 

PUMP Vision  TS350

The first status screen provides*:

  • Contactor failure
  • Overload
  • Ground fault
  • Phase loss
  • Phase reversal
  • Over voltage
  • Under voltage

 

*depending on which MOTOR Vision solution is connected.

 

 

PUMP Vision  TS350

The second status screen provides*:

  • Under current
  • Voltage imbalance
  • High kilowatts
  • Low kilowatts
  • Mechanical jam

 

*depending on which MOTOR Vision solution is connected.

 

 
 

 

PUMP Vision  TS1040

The TS1040 has all of the MOTOR Vision  information off the TS350, but on one screen.

 
 

 

 

 

 

MOTOR Vision "smart" motor starters.  Including:

 

 

MOTOR Vision - U-Line

The Tesys U-Line starter is a complete UL508 E class integrated motor starter.  When coupled with a multi-function trip module and Modbus communication module, it can be connected to the PUMP Vision and provide:

  • Amperes per phase, average and imbalance
  • Ground fault
  • Contact status
  • Mechanical jam, under current, and other important status conditions.

 

 

 

MOTOR Vision - Insight

The Eaton Insight motor monitor/overload relay.  It can be used in conjunction with IEC or NEMA FVNR motor starters and includes a Modbus communication module which can be connected to the PUMP Vision and provide:

  • Voltage per phase, average and imbalance
  • Amperes per phase, average and imbalance
  • Frequency
  • Power factor
  • Ground fault
  • Contact status
  • Mechanical jam, under current, and other important status conditions.

 

 

 

 

 

 

 

 

 

MOTOR Vision - VFD

The PUMP Vision can be setup to operate variable frequency drives such at the Schneider ATV61 and ATV21.  These are connected to the PUMP Vision with Modbus and some important data is displayed, including:

  • Voltage
  • Amperes
  • Frequency
  • Kilowatts
  • Fault conditions and log

*depending on which VFD is connected

 

 

 

 

 

 

 

 

MOTOR Vision - RVSS

The PUMP Vision can be setup to operate reduced voltage soft-start starters such at the Schneider ATS48.  These are connected to the PUMP Vision with Modbus and some important data is displayed, including:

  • Voltage
  • Amperes

*depending on which RVSS is connected